SphygmoCor Px

Aortic Blood Pressure Waveform Analysis
The SphygmoCor Px Aortic BP Profile system is a
non-invasive, doctor’s office device for obtaining
important clinical cardiovascular data. The system does
this by analysing the blood pressure profile where it
really matters – at the heart. The key to the
information the system provides lies in the shape of the
aortic pressure wave. This waveform imparts important
information about the clinical impact of arterial
stiffness on key cardiovascular parameters. The
SphygmoCor system has transformed cardiovascular
evaluation, enhancing patient assessment and management
by providing the following information:
- Evaluation of systemic arterial stiffness (Aortic
Augmentation Index) and its clinical impact on the heart
in increasing patient risk of heart failure, stroke and
myocardial ischaemia.
- Augmentation pressure, which drives left ventricular
load (afterload) - a key parameter affecting risk of LV
hypertrophy.
- Central Pulse pressure in the ascending aorta (driving
cerebral blood flow) giving the true pressure, and hence
the risk of stroke.
- Central systolic pressure, often markedly different
from the cuff value.
- Ejection duration – a parameter for distinguishing
primarily systolic from primarily diastolic dysfunction,
and for managing the efficacy of heart failure therapy.
- Diastolic pressure-time index (DPTI), a key
determinant of coronary blood supply.
- Systolic pressure-time index (SPTI), a measure of
myocardial oxygen demand.
- Subendocardial Viability Ratio – the relationship of DPTI and SPTI, providing a powerful index for risk
stratification for myocardial ischaemia.
Clinical
Applications
- Evaluation of arterial stiffness and its impact on the
heart, giving clinicians an increased ability to assess
disease progression and patient risk.
- Hypertension: Improved patient evaluation in
hypertension by providing a more comprehensive
cardiovascular assessment allowing more effective
treatment and patient management decisions.
- Diabetes: Improved patient treatment in diabetes
through early identification of "at risk" diabetes
patients.
- Heart failure: Differentiation between primarily
systolic and primarily diastolic heart failure, and
management of the progression of diastolic heart
failure.
- Titrating Therapy: Monitoring drug interventions by
assessing their effects at the heart and titrating
therapy accordingly.
- Renal: Measures of arterial stiffness have been shown
to be powerful independent predictors of mortality in
end-stage renal disease.
Research
Applications
- As a quick, reproducible and non-invasive test,
the SphygmoCor Px system provides a tool that can be easily
incorporated into clinical trials.
- The versatile nature of the product has lead to its
inclusion in clinical trials such as pipeline drug
development, discovering early markers for CAD and for
ascertaining independent predictors of morbidity and
mortality.
- With the addition of pulse wave velocity, provides a
complete system to assess arterial stiffness and its
effects.
The various research areas SphygmoCor Px has been used
in include:
- Diabetes – Type 1, Type 2, Insulin resistance,
endothelial function
- Renal – chronic and end-stage renal disease,
transplantation, haemodialysis
- Hypertension – ISH, pseudohypertension,
etc
- Rheumatology
- Pregnancy and pre-eclampsia
- Preventative and alternative medicine
- Heart failure and heart transplantation
Regulatory Status
-
IEC/EN 60601-1 (amendment 1 & 2)
& IEC/EN 60601-1-2 (AS/NZS 3200.1.0 AS/NZS 3200.1.2)
Electromedical Safety Certification (this is a
mandatory requirement for medical equipment to be
used in hospitals in some countries). Rating – “Type
CF Class 2”
-
Device listing with the
Australian Therapeutic Goods Administration (TGA)
-
CE Mark (MDD Annex II)
-
MLHW registration for Japan
-
KFDA Approval for Korea
-
Import License for China
|